From the 1st September 2015 the NRMM regulations apply to:

  1. All major developments
  2. Within Greater London
  3. Using NRMM between 37 and 560KW 

All NRMM these regulations apply to must conform to a set EU Engine Emissions Stage or have an exemption issued by the Greater London Authority.

There are tighter engine emissions standards for developments that fall within the central activity zone (CAZ) and Canary Wharf (View map), and these developments must also use this site to record NRMM usage. 

From the 1st September 2020 tighter standards apply across Greater London, the CAZ and Canary Wharf, and all developments must use this site to record NRMM usage

What is a major development?

Major developments are defined in the London Plan as residential developments of 10 dwellings or more (or, where the number is not given, 0.5 ha or more); and for all other uses, a floor space 1000 m2 or more or a site area 1 ha or more. The site area is that directly involved in some aspect of the development. Floor space is defined as the sum of floor area within the building measured externally to the external wall faces at each level. Basement car parks, rooftop plant rooms, caretakers flats etc. should be included in the floor space figure.

Where is the NRMM Low Emission Zone?

The NRMM Low Emission Zone is comprised of Greater London, the London Central Activity Zone and Canary Wharf.

What NRMM must conform?

All NRMM with a power of between 37KW and 560KW must conform.

What Standard Applies?

From the 1st September 2015

  1. Major Development Sites within Greater London NRMM used on the site of any major development within Greater London will be required to meet Stage IIIA of EU Directive 97/68/EC
  2. Any development site within the Central Activity Zone or Canary Wharf NRMM used on any site within the Central Activity Zone or Canary Wharf will be required to meet Stage IIIB of EU Directive 97/68/EC

1st September 2020

  1. Any development site within Greater London NRMM used on any site within Greater London will be required to meet Stage IIIB of EU Directive 97/68/EC
  2. Any development site within the Central Activity Zone or Canary Wharf NRMM used on any site within the Central Activity Zone or Canary Wharf will be required to meet Stage IV of EU Directive 97/68/EC

What will I have to do?

Site managers at a major development sites in London will need to maintain a list of all on-site NRMM using the GLA's nrmm.london database.

My equipment doesn'™t meet the standards what can I do?

There are a number of options to comply with the requirements of the NRMM policy:

  • Reorganisation of NRMM fleet so that only compliant equipment is used in London
  • Replacing equipment (with new or second hand equipment which meets the policy)
  • Retrofit abatement technologies
  • Re-engining
  • If eligible, apply for an exemption